Neuromuscular transmission electrode/sensor lead Australia - English - Department of Health (Therapeutic Goods Administration)

neuromuscular transmission electrode/sensor lead

ge healthcare australia pty ltd - 59690 - neuromuscular transmission electrode/sensor lead - this device is intended to be non-sterile insulated metal wire(s) designed to conduct electrical signals between neuromuscular transmission (nmt) electrodes and sensors placed on a patient's body and a patient monitoring system module, intended for the monitoring of patient relaxation to determine the level of neuromuscular block and the localization of a nerve in an area of the body. this is a reusable device.

Neuromuscular transmission electrical skin sensor Australia - English - Department of Health (Therapeutic Goods Administration)

neuromuscular transmission electrical skin sensor

ge healthcare australia pty ltd - 59693 - neuromuscular transmission electrical skin sensor - this is intended to be a non-sterile device intended to detect electrical neuromuscular transmission (nmt) signals, from an array of neuromuscular electrodes attached to the surface of the skin of the hand and forearm, or the foot, that are subsequently conducted through an nmt sensor cable to a patient monitoring module to assess the degree of neuromuscular block in a patient. it is typically used for applications when the hand alone cannot be used as the measurement site. this is a reusable device.

Neuromuscular transmission regional anaesthesia block adaptor Australia - English - Department of Health (Therapeutic Goods Administration)

neuromuscular transmission regional anaesthesia block adaptor

ge healthcare australia pty ltd - 59691 - neuromuscular transmission regional anaesthesia block adaptor - this is a non-sterile device intended to conduct electrical signals between itself and an injection needle on a patient?s body, via a neuromuscular transmission (nmt) sensor cable, and subsequently to a patient monitoring module for the localization of a nerve in an area of the body for the administration of regional anaesthesia. this is a reusable device.

Neuromuscular transmission electrode Australia - English - Department of Health (Therapeutic Goods Administration)

neuromuscular transmission electrode

ge healthcare australia pty ltd - 59689 - neuromuscular transmission electrode - this device is intended to be a non-sterile electrical conductor designed to be applied to a patient's body surface, typically the forearm or ankle, to deliver stimulating electrical pulses to a motor nerve or measure electrical impulses from the nerve during neuromuscular transmission (nmt) monitoring. it is typically a disk-like electrode that is affixed to the skin with a special adhesive and a conductive gel (pre-gelled) intended to be used for neuromuscular block monitoring and nerve stimulation for brachial plexus anaesthesia. this is a single-use device.

Neuromuscular transmission motion sensor Australia - English - Department of Health (Therapeutic Goods Administration)

neuromuscular transmission motion sensor

ge healthcare australia pty ltd - 59692 - neuromuscular transmission motion sensor - this is intended to be a non-sterile device intended to be placed on the thumb and index finger of a patient to detect movements and convert them into electrical neuromuscular transmission (nmt) signals during nerve stimulation. the device, also known as a mechanosensor, is a piezoelectric sensor that functions with an nmt sensor cable and skin surface nmt electrodes to transmit electrical signals to a patient monitoring module dedicated to the monitoring of patient relaxation to determine level of neuromuscular block. this is a reusable device

Neuromuscular transmission electrical skin sensor Australia - English - Department of Health (Therapeutic Goods Administration)

neuromuscular transmission electrical skin sensor

draeger australia pty ltd - 59693 - neuromuscular transmission electrical skin sensor - the tofscan nmt monitor is a neuromuscular transmission monitor for monitoring the blocking of patients in the operating theatre, in recovery or in intensive care.

Neurological Stereotactic Surgery System - Stereotactic surgery system, neurological Australia - English - Department of Health (Therapeutic Goods Administration)

neurological stereotactic surgery system - stereotactic surgery system, neurological

emergo asia pacific pty ltd t/a emergo australia - 32568 - stereotactic surgery system, neurological - alpha omega neurosmart system is intended to be used in assisting neurosurgeons in the operating room during functional neurosurgery and to record from and stimulate brain motor and sensory neurons to aid in the placement of depth electrodes.

Neurological Stereotactic Surgery System - Stereotactic surgery system, neurological Australia - English - Department of Health (Therapeutic Goods Administration)

neurological stereotactic surgery system - stereotactic surgery system, neurological

emergo asia pacific pty ltd t/a emergo australia - 32568 - stereotactic surgery system, neurological - the neuro omega system including the drive headstage unit, is intended to assist neurosurgeons in the operating room during functional neurosurgery and to record from and stimulate brain motor and sensory neurons and to aid in the placement of depth electrodes. it is also intended to: - monitor, record and display the bioelectric signals produced by muscles, to stimulate peripheral nerves, and to monitor, record and display the electrical activity produced by nerves to aid the clinician in the diagnosis and prognosis of neuromuscular disease (emg). -measure, record and display the electrical activity of the patient's brain obtained from two or more electrodes on the patient?s head (eeg). -measure, record, and display the electrical activity of the patient's brain obtained from ecog strip and grid electrodes. -provide stimulation via electrode pairs or a hand-held bipolar probe for use in functional brain mapping procedures during treatment of patients with seizure disorder. the device is intended for intraoperative use by medical personnel in hospitals, laboratory, clinic or nursing home settings or outside of a medical facility under direct supervision of a medical professional. the device may also be placed in the intensive care unit or operating room for continuous recording.

Neuromuscular transmission electrical skin sensor Australia - English - Department of Health (Therapeutic Goods Administration)

neuromuscular transmission electrical skin sensor

lateral medical - 59693 - neuromuscular transmission electrical skin sensor - a peripheral nerve stimulator, also known as a train-of-four monitor, is used to assess neuromuscular transmission when neuromuscular blocking agents (nmbas) are given to block musculoskeletal activity.

Neuromuscular transmission electrode Australia - English - Department of Health (Therapeutic Goods Administration)

neuromuscular transmission electrode

ltr medical pty ltd - 59689 - neuromuscular transmission electrode - designed to be used in conjunction with the twitchview system for quantitative monitoring of neuromuscular transmission by means of electromyography, the twitchview single use electrode arrays contain five independent electrodes, two for nerve stimulation and three for emg. the arrays have been designed to work on either the left or right hand. they are intended to be used on an individual patient during a single procedure and then discarded.